An electric well pump stops the moment the grid does, and the house runs on whatever pressurized water is still in the pressure tank. When the power comes back, a submersible pump usually needs only its breaker or overload reset, while a jet pump above ground often has to be primed because air got into the line.

On a well, the household does the work that a water utility does for a house in town. The [EPA's private wells page](https://www.epa.gov/privatewells) puts it plainly: private well owners are responsible for delivering safe drinking water to their households, and the federal Safe Drinking Water Act does not regulate the quality of most private wells. Nobody restarts your pump for you when the lights come back, and nobody tests what comes out of it.

Before any step below, know which of two pumps you own. A submersible pump hangs down inside the well casing, under the water. A jet pump sits above ground, in a basement, a crawl space or a pump house, and pulls water up through a suction pipe. As [Kendisco's priming guide](https://kendisco.com/blog/how-to-prime-a-well-pump/) puts it, submersibles sidestep the priming question entirely by sitting below the water. Most of the confusing advice online about levers and priming plugs comes from mixing those two machines up.

This page draws on Ready.gov, the American Red Cross, the EPA, Franklin Water's jet pump guidance, the reset guides published by pump distributors Kendisco, EveryPump and Well & Septic HQ, and the hand pump specifications on the Simple Pump and Bison Pumps sites.

### Why the pump stops when the power goes out

[Ready.gov's outage page](https://www.ready.gov/power-outages) lists water among the services a blackout can cut off, next to communications and transportation. On a well that line is literal. The motor in the well and the pressure switch that tells it when to run are both on house current.

Kendisco's [pressure switch guide](https://kendisco.com/blog/well-pump-pressure-switch/) says it sits on the pressure tank itself or on the pipe within a few feet of it. In normal times, a dropping tank pressure closes the switch and the pump starts. With the grid down, the switch closes onto a dead circuit and nothing happens.

What keeps the taps running for the first stretch is the tank. It holds a limited volume of water under pressure. Once that is drawn off, the electric pump cannot refill it until the grid returns or a backup source runs the pump.

A long outage can also make the restart harder. [Franklin Water](https://www.franklinwater.com/resources/blogs/why-a-jet-pump-loses-prime-and-how-to-troubleshoot/) warns that an extended power outage can allow water to drain back toward the well, introducing air into the system and causing a jet pump to lose prime. A submersible under the water line is spared that particular problem. For the house as a whole, the [power outage checklist](/grid-down/power-outage-checklist) covers the first hour, and the [long-term outage guide](/grid-down/long-term-power-outage-survival) covers the weeks after it.

### Water you can still use before the tank is empty

The tank's water is the last pressurized water the house will see until the pump runs again. It behaves like any other tap water for the first few draws, and then the pressure falls off and the flow sputters out. How many gallons that is depends on the tank's size and how its switch is set, so the honest answer is a modest amount and an unknown one.

I'd spend it on drinking and cooking. A toilet flush is the quickest way to burn through a tank, because each tank refill draws from the same store. Our [emergency toilet guide](/grid-down/emergency-toilet) covers when a bowl can still be flushed with poured wash water on a septic system and when to switch to two buckets. Hot meals without the range are on the [cooking without power](/grid-down/cooking-without-power) page.

On a jet pump system, the hours the tank sits empty matter too. Franklin's drain-back warning applies to extended outages, and the longer the pump sits idle, the more likely it will need priming before it runs again. That is one more reason to have stored water in jugs, so nobody needs the tank to carry the household for a second day.

### Store drinking and flushing water before the next outage

The water plan that does not depend on the pump is water already sitting in containers. The [Red Cross outage page](https://www.redcross.org/get-help/how-to-prepare-for-emergencies/types-of-emergencies/power-outage.html) advises storing non-perishable food and water supplies for at least two weeks. For a well household that two-week floor carries more weight than it does in town, because a town's pressure can return while your pump still waits for a part or a contractor.

Our page on [water for a two-week grid-down](/stockpiling/water-for-a-two-week-grid-down) works the gallons out per person, and the [emergency water storage planner](/stockpiling/emergency-water-storage-planner-how-many-containers-how-heavy-and-where-they-fit) turns those gallons into containers, weight and the shelf space they need. Flushing water deserves its own count. Toilet water does not have to be drinking water, so a few filled barrels set apart for sanitation keep the drinking jugs for drinking.

Water quality stays your job after the outage too. Under the EPA framework above, the well owner is the one who decides whether the water is safe, which makes stored drinking water the clean fallback while the well's state is unknown.

### How to power a well pump during a blackout

A well pump usually has its own double-pole breaker in the panel. [EveryPump's reset guide](https://everypump.com/blog/well-pumps/how-to-reset-well-pump/) starts its troubleshooting at that double-pole well pump breaker. A two-pole breaker feeds a 240-volt circuit, which is why an extension cord from a small generator's standard outlet will not run the pump.

Starting the motor takes far more than running it. A [well pump wattage guide](https://www.seamlesshome.com/blog/how-many-watts-does-a-well-pump-use) from a home-services site quotes Franklin motor data for a 1/2 HP, 230-volt, two-wire submersible: it runs at 5.0 amps, about 670 watts, and lists 32.2 locked-rotor amps, more than six times its running current. Locked-rotor current is what the motor pulls in the instant it starts. At 230 volts, 32.2 amps is roughly 7,400 volt-amps for that instant. A generator or battery inverter sized only on the 670 running watts will stall or trip as the pump tries to start.

Those figures belong to one motor. Yours are on the motor's label, on the control box label if there is one, or in the well log the driller left. Take them to our page on [what size generator a house needs](/grid-down/generator-sizing-for-a-house), which works from the largest motor's start upward. The [home generator guide](/grid-down/generator-for-home) explains how portable, inverter and standby units connect to the house wiring through a transfer switch. For a battery station, the [solar generator runtime calculator](/grid-down/solar-generator-runtime-calculator-what-it-runs-in-a-blackout-and-for-how-long) shows how long a given battery carries the load once the pump is running.

Exhaust decides where the generator sits. Ready.gov says generators and fuel are always used outdoors and at least 20 feet from windows, doors and attached garages. A pump house can feel like a sheltered spot for the generator, but it fails the open-air rule. Our [carbon monoxide safety guide](/grid-down/carbon-monoxide-safety-during-power-outage) covers detectors and what to do when one sounds.

### Manual well pumps for power outages, by static water level

A hand pump is a second way to draw water from the same well, with no electricity in the loop. Both makers below rate their systems by static water level, the depth at which water stands in the well at rest. Total drilled depth is a different and usually larger figure. Your well report gives the static level, and that is the number to bring to either company.

On published reach, Simple Pump goes deeper: its homepage rates manual operation for static water levels up to 325 feet, with a separate shallow suction model for wells where water stands within 25 feet of the surface. Its pricing page gives only ballpark estimates, because the system depends on your static level and configuration.

Image: simplepump.com

Simple Pump

#### Simple Pump Deep Well Hand Pump

Static water level

Up to 325 ft

Shallow model

Static level under 25 ft

Systems from (Nov 23, 2026)

$855

Pricing

Quoted by static level and setup

For a deep well where the static level sits well past 100 feet.

[See the product page](https://www.simplepump.com/)

Bison's stacked deep well system takes a different route. Its pump basics page rates it for static water levels up to 160 feet, with the cylinder set 20 feet below the static level, and its diagram shows that cylinder stacked in the original drop pipe above the electric submersible. Bison also says its hand pumps can go in alongside an existing submersible in the same casing when the casing diameter allows. Its side-by-side layout is rated separately, so ask Bison with the well report in hand.

Image: bisonpumps.com

Bison Pumps

#### Bison Stacked Deep Well Hand Pump

Stacked system, static water level

Up to 160 ft

Cylinder depth

20 ft below static level

With a submersible

Same casing, when diameter allows

For a household keeping its electric submersible in a casing wide enough to share.

[See the product page](https://www.bisonpumps.com/support/pump-basics/stacked-deep-well-pumps-basics/)

A hand pump is a backup draw path, and it leaves a failed electric pump exactly as broken as it was. What it changes is the outage itself: the well stays usable for drinking, cooking and flushing water while the grid is down, at the cost of arm work.

### Well pump not working after the outage

Start before the power comes back. Ready.gov says to turn off or disconnect appliances, equipment and electronics, because power may return with momentary surges or spikes that can cause damage. For the well, switching its breaker off during the outage keeps the motor out of the first unsteady minutes, and you turn it back on once the grid has held.

If the pump stays silent after that, work from the panel outward, in this order.

**The breaker.** EveryPump points out that a tripped breaker often sits in a middle position that looks on. Push the handle fully off, past that point, and only then switch it back on. If it trips again at once, stop there. The Red Cross goes further: if any breaker tripped during the outage, contact an electrician to inspect it before turning it back on. I'd follow the Red Cross line whenever the breaker was found tripped, and save the off-and-on cycle for a breaker you switched off yourself.

**The control box.** A three-wire submersible system may have a control box on the wall near the tank, and some of those boxes carry an overload with an external reset button. EveryPump quotes Franklin's warning that direct sunlight or another heat source can trip the protectors, and that the box must not be hot to the touch. A hot box gets time to cool before anyone presses reset. A two-wire submersible may have no box on the wall at all.

**The pressure switch.** Watch the tank gauge and listen at the switch. [Well & Septic HQ](https://wellandseptichq.com/blog/how-to-reset-pressure-switch-on-well-pump-without-lever/) uses the click: when pressure falls to the cut-in point, a working switch closes with an audible click. No click with a good breaker points to the switch itself, which their guide calls professional-only work.

### Resetting the pressure switch

Many switches carry a safety that catches people out after an outage. Kendisco explains that a low-pressure cutoff latches out when pressure falls below cut-in, so the pump cannot start into an empty system and destroy itself. A tank drained during a blackout can leave the switch latched, and then the pump stays off even with power at the breaker.

If the switch has a small lever on its side, usually marked for auto, start and off, that lever is the reset. Kendisco's instruction for a switch with a lever is to hold it, which lets the pump run long enough to bring the pressure back up past the cutoff.

Many people search for that lever and find nothing, and the reason is simple. EveryPump says most pressure switches have no lever at all, because it is a factory option, listed by Square D as form letter M4\. A switch without one is reset the way Kendisco describes: restore pressure and cycle the breaker. On a jet pump, restoring pressure means priming first, which the next section covers. On a submersible, turning the breaker fully off and back on is usually the whole job.

If the switch latches out again right away, Kendisco reads that as a system that is not holding pressure: lost prime, low water in the well, or a leak. Leave the cover on the switch. Its contacts carry the pump's full voltage, and the switch itself is work for a well contractor.

### How to prime a well pump after a power outage

This section is for jet pumps and convertible jet pumps above ground. A submersible skips it.

Franklin's re-priming sequence, from its jet pump troubleshooting guide, runs like this:

1. Disconnect power at the circuit breaker and verify that it is off.
2. Remove the priming plug on top of the pump.
3. Fill the pump with clean water until the casing and the suction line are full.
4. Put the plug back and seal it.
5. Restore power and open a faucet.

Kendisco's version matches it and adds two details. Open a faucet downstream before you start, and fill through the plug until water overflows. Once the pump is running, watch the gauge for pressure within about a minute.

Franklin sets the limit on how long to let it try. If the pump does not begin delivering water within approximately 30 seconds, disconnect power and stop the pump. Running a jet pump without water can damage its internal parts, so a second attempt starts with another fill, and the motor is never left churning on air while you wait.

Where the priming plug sits differs from one pump to the next, and the manual for your model shows it. If the pump primes, runs, and loses prime again within the day, that points to the leak or low water Kendisco describes, and more refills will not fix it.

### When to call a well contractor or electrician

The resets above are the homeowner's share of the work. Any of these signs means the pump needs a well contractor or an electrician:

* The pump breaker trips again the moment you reset it (EveryPump).
* A breaker tripped during the outage and has not been inspected (Red Cross).
* The breaker is good, pressure is down past cut-in, and the switch never clicks (Well & Septic HQ).
* The low-pressure cutoff latches out again right after a reset (Kendisco).
* A jet pump gives no water within 30 seconds after a proper fill (Franklin).

Bring what the contractor will ask for: the pump type, the motor label figures, the static water level from the well report, and what the gauge did when you tried the restart.

### My take

I'd start by finding out which pump I own, on a calm afternoon long before the next storm, and I'd judge every reset video by whether it was made for that pump. Walk to the tank, look for a pump beside it with a priming plug on top, and look on the wall for a control box. That five-minute look decides whether a lever video, a priming guide or a breaker reset applies to your house, and most of the frustration I see in reset questions comes from following advice written for the other pump.

Then I'd store the two weeks of water the Red Cross asks for, with flushing water counted separately, and switch the pump breaker off whenever the grid drops. If outages in your county run to days, a hand pump matched to your static water level is the one piece of gear that keeps the well itself in play.

One limit on all the generator math here: a horsepower table is a guess and the motor label is a fact. Read the label before you buy anything to run the pump.

### Frequently asked questions

Does a submersible pump need priming once the power is back? 

No. It sits under the water in the well, so its intake never fills with air. Priming belongs to jet pumps mounted above ground.

Why can I not find a reset lever on my pressure switch? 

Most switches were never fitted with one. The lever is a factory option, so a switch without it is reset by getting pressure back into the tank and turning the pump breaker off and on.

Will a 2000-watt generator run a well pump? 

Running watts are the easy part. The question is the motor's start, which on a small Franklin submersible is over six times its running current, and whether the generator can feed the pump's own two-pole circuit. Work it out from the motor label on our generator sizing page.

How much water is left in the pressure tank when the power drops? 

Only what the tank was holding under pressure at that moment, and that amount varies with the tank and the switch settings. Treat it as a few loads of water and plan your stored jugs for the rest.

Written by

Walt Brenner

Grid-down threats, home security and family plans

Walt Brenner is the pen name of the writer who covers grid-down threats, home security and family emergency plans for Dark Grid Prep. He draws on FEMA and Ready.gov guidance, utility and government reports, manufacturer manuals and long-running prepper forums, and he says plainly where those sources disagree. His beat is the household: what a family of four in a suburb or on a rural lot should have, know and do before the lights go out.

[waltb@darkgridprep.cc](mailto:waltb@darkgridprep.cc)

Last checked 2026-11-23

---

[ ](/) 

Dark Grid Prep is a survival magazine for American families who want to be ready when the grid, the economy or the supply chain fails: the threats (EMP, long blackouts, collapse, civil unrest), and how a household plans, stockpiles, communicates and secures its home through them.

[newsroom@darkgridprep.cc](mailto:newsroom@darkgridprep.cc)

### Prepare

* [Threats and scenarios](/threats)
* [Grid-down living](/grid-down)
* [Stockpiling](/stockpiling)
* [Home defense](/home-defense)

### Plan

* [Bug-out and evacuation](/bug-out)
* [Communications](/communications)
* [Medical](/medical)
* [Family emergency plans](/family-plan)
* [All articles](/articles)
* [All topics](/topics)

### About us

* [About](/about)
* [Authors](/authors)
* [Editorial policy](/editorial-policy)
* [How we make money](/how-we-make-money)
* [Contact](/contact)
* [Terms](/terms)
* [Privacy](/privacy)

© Dark Grid Prep. Written for American families getting ready for grid-down emergencies.

Some links may earn us a commission. It never decides what we write. [How we make money](/how-we-make-money)